Rumored Buzz on Dp50rb
Rumored Buzz on Dp50rb
Blog Article
1.2.2 Warning Labels Warning Labels That means Please meticulously read through this guide just before use product. The next labels can be a. Don't location the unit over a sloped area. In any other case the offered when the procedure product may possibly slide, causing personal harm or perhaps the device is effective With all the cellular malfunction.
The person will not be allowed to open the handles and panel on the method, neither Observe: unit disassemble is authorized. To ensure the technique functionality and protection, only Mindray engineers or engineers authorized by Mindray can conduct maintenance.
Take note: Within the keep track of, the brightness adjustment will come just before contrast. Immediately after readjusting the watch’s distinction and brightness, change all preset and peripheral settings.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Minimize off cable ties connecting the key unit about the display by diagonal slicing pliers, and after that pull out the corresponding cable plugs.
Mindray’s new era of black & white ultrasound procedure, DP-50 Expert, is provided with advanced imaging technologies permitting deeper penetration and more rapidly graphic acquisition with bigger resolution.
The chapter materials the method to validate main functionality and overall performance of product or service. This really is only useful for reference, not preventive execution. Functionality checking and tests of the aspect shall be completed by Mindray provider engineers plus the user jointly. Site sixty six: Standard Exam
Find better diagnostic data by way of extended perspective with the anatomical construction on all convex probes.
iZoom™ allows accurate viewing of graphic from length iWorks™ Protocol aids standardize workflow and lower exam situations
five.two.three Geometric positioning accuracy Longitudinal geometric positioning precision Examination Move: Do changes as the best way in testing the most depth. Document the distance by 20mm Each and every phase around the longitudinal targets line using the measurement caliper; Select the value with the greatest mistake (to 20mm), calculate the precision using the method under The measurement caliper must be positioned within the upper fringe of the focus on, NOTE:... Page seventy nine Transverse geometric positioning precision Examination Move: Go over the scan surface with the phantom with drinking water or couple gel, gently Call the probe Along with the scan surface area Change the depth, earning the transverse targets being displayed within the impression. Change the focus stage for being posited beside the transverse targets (the typical just isn't obvious) Modify parameters like achieve, TGC, generating each transverse targets to become clearly exhibited. Website page 80 five.5.two.four Blackout Spot Take a look at Action: Go over the scan surface in the phantom with drinking water or pair gel, gently Make contact with the probe With all the scan area Alter the depth in a reduce price, and established the main focus at the closest place to the scan surface area. Minimize the value of parameters like AP, Achieve till the track record sounds just may be viewed. Website page eighty one: Computer software Up grade And Maintenance
Just after thriving link, the freshly extra community printer title will probably be revealed while in the printer driver list. Observe: Just before join the network printer, be certain the ultrasound technique and the printer are in the exact same network domain, as well as community is Functioning Ordinarily. The IP deal with as well as server name must be legitimate, e.g. Web page 47 DICOM Location Enter the AE Title from the ultrasound procedure, port and PDU according to the true situation, then click on [Alright] to exit the monitor.
Observe: Right before uploading the log, be certain the ultrasound procedure has long been linked to network, or else, the method might alert “could not connect to server” The server (smtp.
General performance Take a look at 5.five.1 Exam Procedure Resolution Detection depth Geometric Situation Precision Blackout region examination File the exam images 5.five.2 Examination Information The picture applied here is only for reference, keep on with the image influence in the true Be aware: problem. Prerequisites: Show: set the contrast and brightness within the clinical software benefit (or the default standing) Procedure environment: dark space, simulating the medical software environment. Web page 76 In issue the transverse resolution tests targets are horizontally shown, report the negligible length of two targets which can be clearly recognized. Repeat the operation over with the transverse resolution screening targets at other depths. As demonstrated in figure down below. Axial resolution ... Page seventy seven When utilizing the convex probe, hold the transverse resolution screening targets to NOTE: be displayed close to the midline. When employing a linear probe with steer operate, don't turn on the steer perform when accomplish the transverse resolution examination. Zoom in the location exactly where the targets Found if essential. The diameter from the focus on point at a certain depth is equivalent to the transverse resolution at the depth. Website page 78 five.
After replacing the CPU module, key file need to be produced Once more according to the new MAC handle and written into HDD on the device. Or else, the configuration perform on the products might be shed. Following taking away the CPU module, Take out panhead screws with washers (twelve M3X6) fixed on the principle unit box, you usually takes from the board. Web site 118 Determine 8-29 Disassemble the User interface Assembly (one) Hold the higher fringe of user interface assembly, and open up the control panel. Figure 8-30 Disassemble the Dp50rb login User interface Assembly (two) Immediately after eliminating a person countersunk head self-tapping screw PT3X10 fastened around the control panel and choose out the plug with the keyboard and the leading device connecting cables, you could possibly take away the control panel assembly.
Observe: Be certain that you can pull out and force in to the IO board sockets vertically when pulling out and assembling the IO board assembly about the situation on the cope with. Remove panhead screws with washers M3X6 (4) used to safe the IO board, after which you can you may acquire out the IO board. Page 116 Take out panhead screws with washers (2 M3X6) which can be mounted on the leading unit, consider out the upper baffle and afterwards pull out two cables connecting the main board to the facility module assembly.